Beginning of this page
Jump to main content

Please note that JavaScript and style sheet are used in this website,
Due to unadaptability of the style sheet with the browser used in your computer, pages may not look as original.
Even in such a case, however, the contents can be used safely.


SOP


Thermal characteristics

1  

All values are calculated by simulating the test method using a wind tunnel according to the SEMI standard. Air velocity of 0 m/s represents natural convection under still air in the wind tunnel specified in the SEMI standard.

2 Thermal characteristics are affected by environmental conditions such as the density of the copper pattern on the test board, etc.

Type Pin
count
PKG
size[mm]
Die
size[mm]
Thermal
Test Board
Layers
θja(°c/w)
0m/s 1m/s 2m/s
SOP 8 5.0x4.4 2.28x1.97 2

217

- -
SOP 8 5.2x4.4 1.43x1.42 4 216 - -
SOP 14 10.2x4.4 2.06x1.65 4 149 - -
SOP 16 10x7.15 4.22x2.97 2 90 - -
SOP 16 10x7.15 4.22x2.97 4 83 - -
SOP 20 12.5x7.2 4.5x4.5 2 49 39 34
SSOP 16 5.0x4.4 2.28x1.97 2 165 - -
SSOP 20 6.5x6.1 1.44x1.16 2 157 - -
SSOP 20 6.5x6.1 2.59x2.07 2 132 - -
SSOP 24 8.21x6.1 2.01x1.8 4 111 - -
SSOP 30 9.7x6.1 1.574x1.564 2 115 - -
SSOP 30 9.7x6.1 2.18x1.7 2 114 101 -
SSOP 30 9.7x6.1 2.06x2.03 2 112 - -
SSOP 30 9.7x6.1 3.8x3.59 2 110 71 67
SSOP 30 9.7x6.1 4.38x2.44 2 98 - -
SSOP 30 9.7x6.1 6.4x3.5 2 85 - -
SSOP 38 12.3x6.1 2.40x2.01 4 71 - -
SSOP 38 12.3x6.1 6.75x3.39 4 65 - -
SSOP 48 15.8x8 4.9x4.6 2 72 - -
TSSOP 8 4.4x3.1 1.09x1.03 4 221 - -
TSSOP 14 5.2x4.4 1.40x1.23 4 167 - -
TSSOP 26 6.5x6.1 3.6x3.09 4 118 - -