[ID850QB] Setting Debug Environment

Contents

    
FAQ-ID = ID850QB_Setting-nnnn
0883: An error message is displayed during the startup of the ID850NWC, and the ID850NWC cannot be started.
0942: Can N-Wire Card (IE-V850E1-CD-NW) be used with a desk-top PC?
ID850QB_Setting
-0883
An error message is displayed during the startup of the ID850NWC, and the ID850NWC cannot be started.
Q1
An error message is displayed during the startup of the ID850NWC, and the ID850NWC cannot be started.
A1
The following messages may be displayed.

- "F0100: Cannot communicate with in-circuit emulator. Check if device driver for interface board is correctly installed."
- "F03a0: Target power is OFF."
- "F0c70: DCU cannot be accessed."
- "Ff603: ID code is wrong."

Check the following.

If "F0100: Cannot communicate with in-circuit emulator. Check if device driver for interface board is correctly installed." is displayed

[Check]
Check if the device driver for the IE-V850E1-CD-NW has been correctly installed and recognized by the host machine.

[Action]
If the device driver is not correctly installed, it must be re-installed.
Refer to the IE-V850E1-CD-NW User's Manual for the installation procedure.


If "F03a0: Target power is OFF." is displayed

[Check]
Check if the interface signals of the IE-V850E1-CD-NW are correctly connected.

In particular, check the following:

  • Are the pin numbers correct?
  • Is VDD connected in accordance with the specification of the device?
  • Are the flash mode pins (such as FLMD0) connected in accordance with the specification?

[Action]

  • For pin layout, check the wiring by referring to the IE-V850E1-CD-NW User's Manual.
  • Connection of VDD differs depending on the device because the type of buffer power supply (driving power supply) of the N-Wire pins, such as EVDD and BVDD, differ. Check the wiring by referring to the User's Manual of the device used.
  • Be sure to wire the flash mode pin(s) (such as FLMD0) of the device used, if any.


If "F0c70: DCU cannot be accessed." is displayed

[Check]
Check if the interface signals of the IE-V850E1-CD-NW are correctly connected.

In particular, check the following:

  • Are the pin numbers correct?
  • Is the clock supplied in accordance with the specification of the device?
  • Are the flash mode pins (such as FLMD0) connected in accordance with the specification?

[Action]

  • For pin layout, check the wiring by referring to the IE-V850E1-CD-NW User's Manual.
  • Check setting of the frequency (set in the Configuration dialog box) by referring to the ID850NWC User's Manual.
  • Be sure to wire the flash mode pin(s) (such as FLMD0) of the device used, if any.


If "Ff603: ID code is wrong." is displayed

[Check]
Check the following items.

  • Is the ID code correct?
  • Are the flash mode pin(s) (such as FLMD0) connected in accordance with the specification?

[Action]

  • The ID code is a code for security, for which any value can be set.
    For the specification, refer to the User's Manual of the device or the IE-V850E1-CD-NW User's Manual.
    In particular, check if bit 7 of address 0x79 is 1 (N-Wire emulation specification).

    [Caution]
    Note that, if you forget the ID code, the flash memory must be erased (initialized) using the flash memory programmer.

  • Be sure to wire the flash mode pin(s) (such as FLMD0) of the device, if any.


[Reference]
The following items can be tested by the N-Wire Checker.
Check if the interface is correct.

  • Authentication test of ID code
  • Checking frequency of DCK
  • Checking waveform of DDI (check the DDI pin using a measuring instrument.)
  • Checking access to registers of on-chip debug unit
  • Checking access to registers of CPU
N-Wire Checker is installed when the ID850NWC is installed.
Start up the N-Wire Checker as follows:
Select [All Programs] -> [NEC Tools32] -> [N-Wire Checker] from the [Start] menu
For how to use (test method), refer to the ID850NWC User's Manual.
Is this information useful for you ?
back to top  
(2006/08)

ID850QB_Setting
-0942
Can N-Wire Card (IE-V850E1-CD-NW) be used with a desk-top PC?
Q1
Can N-Wire Card (IE-V850E1-CD-NW) be used with a desk-top PC?
A1
N-Wire CARD (IE-V850E1-CD-NW) can be used with a desk-top PC by using a general-purpose PC card adapter of PCI.
Note, however, that some general-purpose PC card adapters of PCI do not operate.
The operation of the following card adapters has been confirmed.
ManufacturerProduct NamePCMCIABusControllerNumber of Slots
MediaFocusCard-Exchanger F16bitRicoh R5C476II2
MediaFocusCard-Exchanger NR16bitCCardBusTI 1420/12111