0939: Time displayed in AnalyzeWindow of AZ850 is not synchronized with the actual time.
AZ850_Trace
-0939
Time displayed in AnalyzeWindow of AZ850 is not synchronized with the actual time.
Q1
Time displayed in AnalyzeWindow of AZ850 is not synchronized with the actual time.
A1
[Soft trace]
  • Time information necessary as AZ trace data is acquired from the timer/counter on the user target. Check if the time set to the timer/counter is correct.

[Hard trace]
  • The actual frequency may differ from the frequency set to ID850.
    Select [Configuration] from the [Option] menu of the ID850, and then check that the value set in "Clock" on the displayed dialog box is the same as the actual frequency.
  • Select [Extended option] from the [Option] menu of the ID850, and check that "Add Up Timetag" is not selected.
    If "Add Up Timetag" is selected, traces of AZ850 are not correctly displayed.