| Caution |
This product will be discontinued. For details on the discontinuation timing, etc., consult the distributor.
|
uPD98408 (Transceiver for ATM switch)
Contents
FAQ-ID = D98408- nnnn
D98408 -0001
|
Initialization
|
| Q1 |
How can I perform initialization of the uPD98408 to the state immediately after reset
via software?
|
| A1 |
This is not possible.
The uPD98408 cannot be initialized by software via internal registers to the state
immediately after reset.
Initialization of this LSI can be done only by inputting the reset signal to the
RESET_B pin.
|
 |
|
(2005/08)
|
 |
|
| Q1 |
Is the interval (bit count) between adjacent pairs of signs separated by the IDLE pattern
in the PHY output direction so as to be an integral multiple of the sign pair
length (10 bits)?
|
| A1 |
Yes, that is correct.
|
 |
|
(2005/08)
|
 |
|
D98408 -0003
|
Noise countermeasure
|
| Q1 |
Regarding AC line noise, ATM25 noise resistance using the uPD98408 is lower than
that of other communication ports (100BASE-T, ATM155).
|
| A1 |
For information on A1 noise countermeasures, refer to the
Q&A section.
|
 |
|
(2005/08)
|
 |
|
|